Aerosol Data: Particulate Matter (PM2.5) mass and Black Carbon (BC) concentrations and Gas Phase Data: Carbon monoxide, Ozone, and Nitrogen oxides measured at Fort Stewart in 2022 during prescribed burning events.

The data is collected at one Georgia Tech instrumented trailer located at two different locations (shown in the locations information) from March 2 till 6, 2022. Trailer was set in the mentioned locations based on the planned burns of units F6.3 and F6.2 on March 2, 3 and units E16.2 and E16.3 on March 5. This data was collected to improve the characterization of Ozone (O3) and Particulate matter (PM) formation in prescribed fire plumes through measurement.

Data en bronnen

Extra Informatie

Veld Waarde
Laatst gewijzigd juli 2, 2025, 21:57 (UTC)
Gecreëerd juli 2, 2025, 21:57 (UTC)
Bron https://wfsi-data.org/view/doi%3A10.60594/W47G61
award An Improved Understanding of Fuel Dynamics, Fire Behavior and Regional Air Quality Impacts of Prescribed Burning at DoD Lands
creators Rime El asmar, rasmar3@gatech.edu, Georgia Institute of Technology, https://orcid.org/0009-0000-8231-7498 | Talat Odman, talat.odman@ce.gatech.edu, Georgia Institute of Technology, https://orcid.org/0000-0002-3947-7047
doi doi:10.60594/W47G61
funder U. S. Department of Defense (DoD), Strategic Environmental Research and Development Program (SERDP) , http://dx.doi.org/10.13039/100013316
maintainor Rime El asmar, rasmar3@gatech.edu
method Data Limitation: PM2.5 mass was measured using a Tapered Element Oscillating Microbalance (TEOM) series 1400a ambient particulate monitor (Thermo Fisher Scientific). TEOM is a gravimetric measurement that determines the mass accumulated on a microbalance over a specified time interval and monitored sample air flow rate. Mass concentration over an averaging period is calculated from the difference recorded between successive intervals. Due to random fluctuations in the instrument operation when concentrations are low, this can lead to negative numbers. PM2.5 mass concentration data was recorded at an averaging time of 60 seconds and limit of detection (LOD) of 5.58 µg/m3 determined by 3 standard deviations of blank measurements for the TEOM used in this study. The data reported can be averaged over 20 or 30 minutes to mitigate noise, especially when sampling background conditions, i.e., PM2.5 mass concentrations are low and approaching the LOD.
project Funding Award RC20-1047: An Improved Understanding of Fuel Dynamics, Fire Behavior and Regional Air Quality Impacts of Prescribed Burning at DoD Lands
spatial {"type": "Polygon", "coordinates": [[[-81.702404, 32.0546325], [-81.8842058, 32.0546325], [-81.8842058, 32.0663665], [-81.702404, 32.0663665], [-81.702404, 32.0546325]]]}
temporal {"endTime": "2022-03-06", "startTime": "2022-03-02"}